Off-Grid Wandler

Off-Grid Inverter
Sort By:  
Off Grid Inverter 6KW to 10KW
Off Grid Inverter 1KW to 5KW
Off Grid Inverter 6KW to 10KW

MI 8KVA-15KVA   Off Grid Inverters (6KW to 10KW)

MPPT- Models

MI-8KVA

MI-10KVA

MI-12KVA

MI-15KVA

Rated power

6000W

7000W

8000W

10000W

Battery voltage

                          48/96V

N.W./ G.W

            38/43KG                  40/47KG                  45/52KG                      53/60KG

Dimension L×W×H(mm)

570×340×240(mm)

Package size L×W×H(mm)

620×380×330(mm)

Inverter

AC Input voltage range(VAC)

170-275VAC(220V)        85-138VAC(110V)

Input frequency(Hz)

45-65HZ

Battery voltage range

10.5-15VDC (Single battery voltage)

Output voltage range(VAC)

Inverter mode 110V/220V/230V/240V±2%

Utility output voltage range

constant voltage output 220VAC±10%    110VAC±10%

Output frequency(Hz)

50/60±1%.

Utility output frequency range

50Hz 60Hz automatic tracking

Output waveform

Pure sine wave

Efficiency

90%

THD

≤3%

Transfer time(ms)

≤4ms

Charging type 

U0-U7

Charging current

C0=0A, C1=5A, C2=10A, C3=15, C4=20A, C5=25A, C6=30A

Battery Lack-voltage alarm/protection   

48V(42V/40V)

96V(84V/80V)

Battery over-voltage alarm/ protection

48V(60V/66.8V)

96V(120V/133.6V)

 

 

Inverter

Overload protection

Rated power≥110%,60S power off;≥130%, 10S power off;≥150%,0.6S power off。.

Temperature protection

≥85℃ Alarm,≥90℃ Shutdown the machine

 Working mode

01.   Normal Mode: Utility is preferred, Utility is charging ;

02.   Eco Mode: Load power≤10% shutdown the machine,≥ 11%-100% turn on;

03.   ≥13V≤10.5V

Solar inverter is preferred, Utility is not charging, charging: battery voltage≥13V switch to inverter mode; Inverter: battery voltage≤10.5V, switch to utility mode

 

Solar power 

Controller

Solar rated voltage

72V    

           144V 

Maximum input voltage

84V/160V(PWM/MPPT)

       190V(MPPT)

Charging voltage

   54V /57.2V(PWM/MPPT)

       114.4V (MPPT)

Charging current

MPPT 50A /60A /80A/100A/120A

PWM  50A/60A/100A Optional

 

MPPT:40A/80A Optional

Protection type   

Solar cells, anti-anti-charge protection, battery open-circuit protection, battery reversal protection

Overcharging protection voltage  

60V

     120V

Over discharge   

40V

80V

MPPT

System voltage automatic recognition

40V-60V

80V-120V

Maximum PV open circuit voltage (Voc)

160V

190V

Max efficiency

   ≥98.1% (Voc is 1.5 or 2 times than battery, then it’s best efficiency)

Cooling method

Auto detective cooling fan                                   ≤42℃ Fan slow turning heat dissipation,≥45℃ Fan high turning heat dissipation                 

Display

LCD inverter output voltage, input AC voltage, battery capacity percentage, load capacity percentage, Solar input voltage, generating capacity Solar charge current,  etc...)

 

                     

 

 

Off Grid Inverter 6KW to 10KW
Off Grid Inverter 1KW to 5KW

MIPI1KW-5KW  OFF GRID Solar Inverters

Model Number

DSOG1

DSOG1.5

DSOG2

DSOG3

DSOG3.5

DSOG4

DSOG5

MPPT一 Models

MI-1.5KVA

MI-2KVA

MI-3KVA

MI-4KVA

MI-5KVA

MI-6KVA

MI-7KVA

Rated power

1000W

1500W

2000W

3000W

3500W

4000W

5000W

Battery voltage

24V

24/48V

48V

Net weight

13KG

15KG

17KG

20KG

25KG

27KG

30KG

Dimension L×W×H(mm)

440×310×132(mm)

485×350×182(mm)

Package size L×W×H -mm

495×360×190(mm)

540×400×240(mm)

 

Inverter

AC Input voltage range(VAC)

                            170-275VAC(220V)                    85-138VAC(110V)

Input frequency(Hz)

45-65HZ

 

Battery voltage range

10.5-15VDC (Single battery voltage)

Output voltage range(VAC)

Inverter mode 110V/220V/230V/240V±2%

Utility output

voltage range

                            Constant voltage output 220VAC±10%                             110VAC±10%

 

Output frequency(Hz)

50/60±1%.

Utility output frequency range

50Hz 60Hz automatic tracking

 

Output waveform

Pure sine wave

Efficiency

85%

THD

≤3%

 

Transfer time(ms)

≤4ms

 

Charging type

U0-U7 (7 Battery Types are available)

 

 

Charging current

C0=0A, C1=5A, C2=10A, C3=15, C4=20A, C5=25A, C6=30A

Battery

Lack-voltage alarm/protection

24V(21V/20V)

48V(42V/40V)

Battery

over-voltage alarm/ protection

24V(30V/33.4V)

48V(60V/66.8V)

Overload protection

Rated power≥110%,60S power off;≥130%,10S power off; ≥150%,0.6S power off

Temperature protection

≥85℃   alarm,≥90℃s shutdown the machine

Working mode

01.Normal Mode: Utility is preferred, Utility is charging

02 Eco Mode: loadpower≤10% shutdown the machine,≥11%-100% turn on

03 Solar inverter is preferred, Utility is not charging, charging: battery voltage≥13V switch to inverter mode; Inverter: battery voltage≤10.5V, switch to utility mode

Solar

Controller

 

Solar rated voltage

36V

72V

Maximum input voltage

42V/105V(PWM/MPPT)

84V/150V(PWM/MPPT)

(DC)Charging voltage

27V/28.6V(PWM/MPPT)

54V /57.2V(PWM/MPPT)

Charging current

30A/ 40A/ 50A /60A Optional

Protection type

Solar cells, anti-anti-charge protection, battery open-circuit protection, battery reversal protection

 

Overcharging protection voltage

30V

60V

Over discharge

20V

40V

MPPT

 

System voltage automatic

recognition

18V-29V

40V-60V

Maximum PV open      circuit

voltage (Voc)

160V

Max efficiency

                            ≥98.1%           (Voc is 1.5 or 2 times than battery, then it’s best efficiency)

Cooling method

Auto detective cooling fan≤ 42℃   Fan slow turning heat dissipation,≥45℃   Fan high turning heat dissipation

Display

LCD (inverter output voltage, input AC voltage, battery capacity percentage, load capacity percentage, Solar input voltage, generating capacity, Solar charge current, etc...)

Off Grid Inverter 1KW to 5KW
Per Page      1 - 2 of 2